"Complement" means it complements, or helps, other immune defences. It was named because scientists found that these blood proteins helped antibodies destroy microbes. We now know complement can also work without antibodies.
"Pathways" are different routes for switching those proteins on, like a chain of falling dominoes:
- Classical: usually starts when antibodies attach to a target.
- Lectin: starts when a recognition protein binds sugars on a microbe.
- Alternative: starts through low-level background activation that gets amplified on microbial surfaces.
All three converge on C3, a central complement protein, producing three main effects:
- Tag microbes for immune cells to eat.
- Recruit immune cells and increase inflammation.
- Punch holes in susceptible microbes using the membrane attack complex, MAC.
Three entrances, same defence system: tag, call, kill.
Lab words
- Assay: a test. Analyte: whatever it measures, such as an antigen, antibody or cytokine.
- Antigen: a molecule an antibody recognises. Epitope: the particular part it binds. A known antibody can detect an unknown antigen; a known antigen can detect antibodies against it.
- Reagent: a substance added to perform the test. Label: a measurable tag attached to a reagent, making otherwise invisible binding detectable.
- Affinity: strength of one antibody-binding interaction, not antibody amount or simply binding speed. Lower Kd, the dissociation constant, means higher affinity.
- Monoclonal: one B-cell clone, one epitope specificity. Polyclonal: several clones recognising multiple epitopes. Either can show cross-reactivity, binding a similar unintended target.
ELISA: enzyme-linked immunosorbent assay
- An antibody-antigen interaction holds an enzyme label in a plastic well. Add a substrate, the substance the enzyme acts on, to generate colour. The plate reader measures absorbance / optical density (OD), not concentration directly.
- Direct ELISA: attach antigen to the well, block unused surface, add enzyme-labelled antibody, wash, then add substrate. The labelled antibody binds the antigen itself.
- Indirect ELISA for patient antibodies: known antigen on plate → block → patient serum → wash → enzyme-labelled anti-human antibody → wash → substrate. The patient's antibody is the analyte. The anti-human antibody is a reagent that recognises it.
- Sandwich ELISA for antigen: capture antibody on plate → block → sample antigen → wash → detection antibody → wash → substrate. Here the detection antibody carries the enzyme; other versions add another labelled reagent. The two antibodies bind different accessible epitopes.
- Sandwich = antibody-antigen-antibody. More antigen usually gives more signal within the working range. Example: measuring IL-6 concentration.
Competitive immunoassay
- In the format tested here, sample analyte competes with a fixed amount of labelled analyte for limited antibody-binding sites. Separate bound from unbound material and measure the bound label.
- More sample analyte → less labelled analyte binds → lower signal. This is the reverse of the usual sandwich response.
- Useful for small molecules with only one accessible epitope. The label can be an enzyme, a fluorescent tag or a radioisotope; competition does not require one particular label.
Blocking, washing and controls
- Blocking covers unused plate sites so unrelated proteins do not stick there. Washing removes unbound material. Leftover enzyme-labelled reagent can create a falsely high signal.
- Blank: measures reagent background. Negative control: should not react. Positive control: should react. Failed controls mean sample results cannot be trusted.
- Standards / calibrators: known concentrations used to make a calibration curve. Match the sample signal to that curve; do not assume it is linear everywhere. Independent quality controls check whether the measurement is working correctly.
- Dilution: 1:10 means one part sample in ten total parts. If the diluted sample measures 2 ng/mL, the original is 2 x 10 = 20 ng/mL, unless the instrument already applied that correction.
- Hook effect: extremely high antigen can prevent proper sandwich formation and produce a falsely low result. Appropriate dilution and repeat testing can reveal it.
Labels and sensitivity
- Chromogenic substrate: becomes coloured after enzyme action. Chemiluminescence: a chemical reaction produces light. Fluorescence: a tag emits light after excitation by light. Radioisotope: detected through radioactive emissions.
- Analytical sensitivity: ability to detect small amounts of analyte. In the quiz comparison, enzyme plus chromogenic substrate gives high, but not extremely high, sensitivity. Actual detection limits depend on the whole assay.
- A label makes binding measurable; it is not primarily what attaches the antibody to the plate. Antibody-based tests are useful, but are not the only way to study molecules.
Agglutination and blood grouping
- Agglutination: antibodies cross-link cells or particles into visible clumps. Haemagglutination: specifically red-cell clumping. IgM is particularly effective because it has multiple binding sites.
- For forward ABO grouping, mix red cells separately with anti-A and anti-B reagents. Clumping with anti-A means A antigen is on the cells, not that the patient's serum contains anti-A.
- Anti-A only → A; anti-B only → B; both → AB; neither → O, subject to valid controls and full grouping checks.
- Haemagglutination is used for blood grouping and red-cell antibody testing, not routine measurement of clotting factors. Clumping is not coagulation, the process that makes a fibrin clot.
- Direct (DAT): wash the patient's red cells, then add anti-human globulin, a reagent against human antibody and/or complement. Clumping indicates these were already attached to the patient's cells.
- Indirect (IAT): incubate patient serum/plasma with test red cells, wash, then add anti-human globulin. It detects free antibodies in the sample that can bind those cells.
- Direct = on cells already. Indirect = antibodies in serum. A positive DAT does not by itself prove that red cells are being destroyed.
Precipitation and immunodiffusion
- Precipitation: soluble antigen and antibody form a large insoluble network. Unlike agglutination, the starting antigen is dissolved, not carried on a cell or particle.
- Radial immunodiffusion: place antigen in a well in antibody-containing gel. It spreads out and forms a precipitate ring. At the validated endpoint, compare ring diameter squared with standards to estimate concentration.
- Double immunodiffusion: antigen and antibody diffuse from separate wells; a visible precipitin line forms where their proportions allow a network to form.
- Equivalence: suitable antigen-antibody proportions. Prozone: antibody excess. Postzone: antigen excess. Either excess can reduce visible precipitation or clumping.
Nephelometry versus turbidimetry
- Mix sample with antibody against the target protein. Immune complexes form; compare their optical signal with calibrators to measure proteins such as total IgG or C3.
- Nephelometry measures scattered light. Turbidimetry measures the loss of transmitted light as the mixture becomes cloudy.
- Neither principle requires an enzyme label or chromogenic substrate. Immunodiffusion is read as rings or lines in gel; do not describe it as an instrument measuring scattered light.
Rapid tests and automated analysers
- Point-of-care (POC): testing near the patient. Aim for simple steps and no equipment or portable equipment. It must be suitable for its purpose, but does not have to be the most sensitive and specific test available.
- Lateral-flow test: add sample/buffer → liquid moves along a strip → labelled material binds at a test line. For a typical sandwich test: C + T = positive; C only = negative; no C = invalid. C means control; T means test. Read within the kit's time window; competitive strips can use different rules.
- Automated immunoanalysers handle pipetting, incubation, separation/washing and signal reading. The quiz's claim that washing must still be done by hand is false. Calibration and quality controls are still needed.
Other course methods: recognise what each tells you
- Immunofluorescence: antibody binding plus a fluorescent label shows where a target is in cells or tissue. Direct uses a labelled primary antibody; indirect uses a labelled secondary antibody that binds the primary antibody.
- Western blot: separate proteins by size in a gel → transfer to membrane → block → primary antibody → wash → labelled detection reagent → wash → detect bands. Band position indicates approximate protein size; intensity can estimate relative amount within the valid range.
- Flow cytometry: stain cells with fluorescent antibodies, wash, then pass cells individually through a laser. Select a cell population by gating and measure its markers. CD3 identifies T cells; CD3+ CD4+ identifies helper T cells; CD19 identifies B cells. Counts alone do not prove normal cell function.
Reading a result
- Diagnostic sensitivity: proportion of people with the disease who test positive. Diagnostic specificity: proportion without the disease who test negative. These are different from detecting very small molecular amounts.
- Titre: highest sample dilution that still tests positive. Positive at 1:160 but negative at 1:320 → titre 1:160, sometimes reported as 160.
- Antigen test = looks for the target itself. Antibody test = looks for the person's response. Antibodies may persist after infection; a negative early antibody result can occur before enough antibody has formed.