1. Dead space and alveolar ventilation

Dead space and its types
Dead space is inspired air not participating in gas exchange. Anatomical: conducting airways, about 150 mL. Alveolar: ventilated but inadequately perfused alveoli, nearly zero in healthy lungs. Physiological = anatomical + alveolar.
Alveolar ventilation
Fresh air reaching gas-exchanging alveoli per minute: VA = (VT - VD) x respiratory rate. With VT 500 mL, VD 150 mL and 12/min: 4.2 L/min.
Bohr equation and principle
VD/VT = (PACO2 - mixed expired PCO2) / PACO2. Dead-space gas dilutes expired CO2. With 40 and 28 mmHg: VD/VT = 0.30; VD = 150 mL for VT = 500 mL. Then calculate VA = (VT - VD) x rate.

Per breath: 500 mL enters, about 150 mL stays in dead space and 350 mL reaches alveoli. Per minute: multiply by respiratory rate.

2. Vital capacity

Definition and subdivisions
VC is the maximum volume exhaled after maximal inspiration. VC = VT + IRV + ERV, about 4-5 L. Example components: VT 0.5 L, IRV 3 L, ERV 1.1 L.
Measurement
Spirometry: inhale maximally, then exhale maximally. Open-system devices measure airflow and integrate it into volume; closed systems measure volume changes in a sealed gas system.

3. RV, FRC and TLC

Definitions, values and formulas
RV: air after maximal expiration (~1.2 L). FRC: air after quiet expiration (~2.3-2.5 L), FRC = ERV + RV. TLC: air after maximal inspiration (~5-6 L), TLC = VC + RV.
Measurement
Simple spirometry cannot measure RV, FRC or TLC. Measure FRC by helium dilution or body plethysmography; use spirometry for ERV and VC. RV = FRC - ERV; TLC = VC + RV.

Helium stays in the communicating gas space. Its dilution reveals lung volume at connection; connect after quiet expiration to measure FRC.

Calculation examples

4. Pressures, volume and airflow during a breath

Alveolar and intrapleural pressures
Relative to atmosphere: at rest PA = 0 and Ppleural ~-3 mmHg. Inspiration: pleural pressure falls towards -6; PA briefly falls to ~-1, then returns to 0. Expiration: pleural pressure returns towards -3; PA briefly rises to ~+1, then returns to 0.
Lung volume and airflow
Volume rises during inspiration and falls during expiration. It is highest at end-inspiration and lowest at end-expiration. Flow is inward during inspiration and outward during expiration; zero at both endpoints, with peaks between them.

Transpulmonary pressure = alveolar pressure minus intrapleural pressure. It keeps the lung expanded. Inward and outward flow signs depend on the graph convention.

PDF p. 3

5. Pulmonary perfusion, shunt and V/Q

Flow and pressure
Pulmonary perfusion equals approximately cardiac output: 5 L/min at rest. Pulmonary-artery pressure is about 25/8 mmHg.
Shunt
Shunt is blood reaching systemic arteries without being oxygenated by ventilated alveoli. Anatomic shunt includes bronchial venous blood entering pulmonary veins and Thebesian drainage into the left heart; small normal venous admixture is about 2%. Functional shunt is perfusion of unventilated alveoli.
V/Q and its gradient
Whole-lung alveolar ventilation/perfusion is about 0.8 (4/5 L/min). Both ventilation and perfusion are greater at the base, but perfusion changes more, so V/Q is higher at the apex and lower at the base.

Dead space: air without effective blood flow. Shunt: blood without ventilation. Normal apex blood flow is reduced, not normally absent.

6. Alveolar membrane and diffusion

Membrane
Alveolar lining and type I epithelium, thin/fused basement membranes and interstitium, and capillary endothelium. Very thin (<1 micrometre) with a large surface area (~70-100 m2).
Directions and pressure gradients
O2 moves from alveoli (~100 mmHg) to incoming mixed venous blood (~40). CO2 moves from incoming blood (~46 mmHg) to alveoli (~40).
Fick's law
Diffusion rate = surface area x diffusion coefficient x partial-pressure difference / membrane thickness. More area or gradient increases diffusion; greater thickness reduces it.

Dry atmospheric PO2 is about 160 mmHg; humidified inspired PO2 is about 150; alveolar PO2 is about 100.

7. Oxygen transport and the dissociation curve

Transport and oxygen content
Mostly bound to hemoglobin; a small amount dissolved. Each Hb binds up to 4 O2; 1 g Hb binds ~1.34 mL O2. Content (mL/L) = 1.34 x Hb (g/L) x saturation fraction + 0.03 x PO2 (mmHg). Arterial ~200 mL/L; mixed venous ~150 mL/L; difference ~50 mL/L.
Curve and reference points
Sigmoid curve: saturation versus PO2, due to cooperative binding. Approximate PO2/saturation pairs: 26/50%, 40/75%, 60/90%, 100/97%.
Shifts
Higher CO2, lower pH, higher temperature or higher 2,3-BPG shift right: lower affinity and more tissue unloading. Opposite changes shift left. The CO2/pH effect is the Bohr effect.

PO2, saturation and oxygen content are different quantities. Use saturation as a fraction in calculations. The Bohr effect refers to CO2/pH, not temperature alone.

PO2 (mmHg)Approximate SO2
2650%
4075%
6090%
10097%
Calculation examples

8. CO2 transport and the chloride shift

Transport and enzyme
About 70% as bicarbonate, 20% bound to proteins (including carbaminohemoglobin), 10% dissolved. RBC carbonic anhydrase speeds CO2 + H2O <-> H2CO3 <-> H+ + HCO3-.
Tissues and lungs
Tissues: CO2 enters blood/RBCs; HCO3- leaves RBCs and Cl- enters. Lungs: HCO3- enters RBCs and Cl- leaves; bicarbonate becomes CO2, which diffuses into alveoli.
CO2 curve and Haldane effect
CO2 content increases with PCO2, approximately linearly over the physiological range. Deoxygenated blood holds more CO2 at the same PCO2. Oxygenation in lungs promotes CO2 release: the Haldane effect.

Bohr effect: CO2/H+ changes O2 binding. Haldane effect: oxygenation changes how much CO2/H+ blood carries.

9. Chemoreceptors and the three experiments

Central chemoreceptors
In the medulla. CO2 crosses into CSF and raises H+ (lowers pH), stimulating ventilation. Central receptors do not directly sense low arterial O2.
Peripheral chemoreceptors
Carotid bodies at carotid bifurcations (CN IX) and aortic bodies (CN X). Respond to low PaO2, high PaCO2 and low arterial pH. The hypoxic response becomes strong below about 60 mmHg PaO2.
Three experiments
Experiment 1: O2 falls and CO2 rises, largest ventilation increase. Experiment 2: only O2 falls, smallest increase in this practical. Experiment 3: only CO2 rises, intermediate increase. Hypoxia and hypercapnia reinforce each other.

The response ranking applies to this practical. Low oxygen content in anaemia is not the same as low arterial PO2.

10. Breathing at high altitude

Gas and immediate responses
Barometric pressure and inspired PO2 fall; oxygen fraction remains ~21%. Hypoxia increases ventilation and initially heart rate/cardiac output. Hyperventilation lowers CO2 and causes respiratory alkalosis. Widespread hypoxic pulmonary vasoconstriction raises pulmonary pressure.
Acclimatisation
Over days, kidneys excrete bicarbonate, helping sustain ventilation. Over weeks, renal erythropoietin increases red-cell/Hb mass and O2-carrying capacity. Higher 2,3-BPG favours unloading; alkalosis initially favours a left shift. Adaptations differ among high-altitude populations.

More Hb raises oxygen-carrying capacity; it does not itself shift the oxygen-dissociation curve.

11. Diving and decompression sickness

High pressure and decompression
Higher gas partial pressures dissolve more nitrogen in blood and tissues. High nitrogen partial pressure can cause narcosis. Rapid decompression allows dissolved nitrogen to form bubbles: decompression sickness (caisson disease).
Prevention
Use a controlled ascent and appropriate decompression schedule/stops; avoid rapid decompression.

Nitrogen narcosis occurs at high pressure; decompression sickness is caused by bubbles as pressure falls.

Short questions

QuestionAnswer
1. What is an adult's tidal volume at rest?

About 500 mL per breath.

2. What is an adult's resting respiratory rate?

About 12-16 breaths/min.

3. What is an adult's minute ventilation at rest?

About 6 L/min.

4. A breathing cycle lasts 3 seconds and tidal volume is 0.4 L BTPS. Calculate minute ventilation.

8 L/min.

5. Alveolar dead space consists of alveoli that are not ventilated, or that have no blood flow?

Ventilated alveoli with no effective blood flow.

6. FEV1 is 2 L and VC is 4 L. Calculate the Tiffeneau index. Is it within the normal range?

Tiffeneau index: 50%.

Interpretation: Below normal; suggests airflow obstruction.

7. What is the systolic pressure in the pulmonary artery?

About 25 mmHg.

8. What is the value of inspired O2 fraction FiO2 in room air?

About 21% (0.21).

9. What is the value of inspired CO2 fraction FiCO2 in outdoor air?

About 0.04% (0.0004), effectively near zero for these calculations.

10. Why is expired FCO2 nearly zero at the start of expiration, and where does gas at the end of expiration come from?

Start: conducting-airway dead-space gas. End: mainly alveolar gas, with the highest CO2 fraction.

11. What is an adult's resting oxygen consumption per minute?

About 250 mL O2/min.

12. In the upright position, is the V/Q ratio greater at the lung apex or base?

At the apex.

13. What is resting alveolar PACO2?

About 40 mmHg.

14. What is resting alveolar PAO2 near sea level?

About 100 mmHg.

15. What is mixed venous PvCO2 at rest?

About 46 mmHg.

16. How does PCO2 affect the hemoglobin oxygen-dissociation curve?

Higher PCO2: right shift, lower affinity, more unloading. Lower PCO2: left shift.

17. How does pH affect the hemoglobin oxygen-dissociation curve?

Lower pH: right shift, lower affinity, more unloading. Higher pH: left shift.

18. How does temperature affect the hemoglobin oxygen-dissociation curve?

Higher temperature: right shift, lower affinity, more unloading. Lower temperature: left shift.

19. Calculate hemoglobin-bound O2 content when PO2 is 40 mmHg and Hb is 120 g/L. Use 1.34 mL O2/g Hb.

About 121 mL O2/L blood.

Working
20. Calculate hemoglobin-bound O2 content when PO2 is 26 mmHg and Hb is 150 g/L. Use 1.34 mL O2/g Hb.

About 101 mL O2/L blood.

Working
21. Calculate hemoglobin-bound O2 content when PO2 is 60 mmHg and Hb is 150 g/L. Use 1.34 mL O2/g Hb.

About 181 mL O2/L blood.

Working
22. What is the normal resting arteriovenous oxygen difference?

About 50 mL O2/L blood.

23. Arterial O2 content is 200 mL/L and venous content is 152 mL/L. Calculate the arteriovenous oxygen difference.

48 mL O2/L blood.

24. At 5,000 m, barometric pressure is 387 mmHg and water-vapor pressure is 47 mmHg. If FAO2 is 14%, calculate alveolar PO2.

47.6 mmHg.

Working
25. Barometric pressure is 757 mmHg, water-vapor pressure is 47 mmHg, and alveolar CO2 fraction is 5%. Calculate PACO2.

35.5 mmHg.

Working
26. Barometric pressure is 747 mmHg and water-vapor pressure is 47 mmHg. If alveolar PO2 is 70 mmHg, calculate FAO2.

10% (0.10).

Working
27. If CO2 production stays constant while alveolar ventilation increases, how does alveolar PCO2 change?

It decreases.

28. Which lung volumes cannot be measured using spirometry alone?

Functional residual capacity (FRC) and residual volume (RV).

29. A spirometer contains 8 L gas with helium concentration 5%. After the subject breathes from it, helium concentration is 4%. Calculate lung gas volume at connection.

2 L.

Working
30. Find respiratory rate from the subject's spirogram.

Rate = complete breaths / recording time in minutes (or breaths / seconds x 60). A numeric rate cannot be calculated from this figure because no time scale is provided.

Graph
31. Find the values of FRC and VC from the spirogram.

FRC: About 3.2 L.

VC: 4 L.

Graph
32a. Add labels 1-8 to the lung-volume diagram.

1: Tidal volume (VT or TV).

2: Inspiratory reserve volume (IRV).

3: Expiratory reserve volume (ERV).

4: Residual volume (RV).

5: Vital capacity (VC).

6: Inspiratory capacity (IC).

7: Functional residual capacity (FRC).

8: Total lung capacity (TLC).

Graph
32b. Read TLC, RV, FVC and PEF from each forced expiratory flow-volume curve.

Left curve: TLC, RV, FVC, PEF: TLC 6 L; RV 2 L; FVC 4 L; PEF about 8 L/s.

Right curve: TLC, RV, FVC, PEF: TLC and RV cannot be read from this expired-volume curve. FVC about 4.5 L; PEF about 8 L/s.

Graph

Formulas

Short Q19-21: hemoglobin-bound oxygen

Bound O2 content = 1.34 x Hb x SO2

Hb in g/L; SO2 as a fraction; answer in mL O2/L blood. Read SO2 from the oxygen-dissociation curve first.

QuestionPO2 and saturationCalculation
1940 mmHg -> 75% = 0.751.34 x 120 x 0.75 = 120.6, about 121 mL O2/L
2026 mmHg -> 50% = 0.501.34 x 150 x 0.50 = 100.5, about 101 mL O2/L
2160 mmHg -> 90% = 0.901.34 x 150 x 0.90 = 180.9, about 181 mL O2/L

These questions ask for Hb-bound oxygen only. For total oxygen content, also add 0.03 x PO2 with these units. If Hb is in g/dL, the result is mL/dL and the dissolved coefficient is 0.003.

Short Q24-26: gas fractions and partial pressures

Pgas = Fgas x (PB - PH2O) | Fgas = Pgas / (PB - PH2O)

PB is barometric pressure. PH2O is water-vapour pressure: 47 mmHg at 37 C. Use the fraction given for that gas, not automatically 21%.

QuestionSubstitutionAnswer
24PAO2 = 0.14 x (387 - 47)47.6 mmHg
25PACO2 = 0.05 x (757 - 47)35.5 mmHg
26FAO2 = 70 / (747 - 47)0.10 = 10%

Subtract water-vapour pressure before multiplying or dividing. Convert percentages to fractions: 14% = 0.14; 5% = 0.05. Q25 is CO2, despite the O2 subscripts in the PDF working.

Short Q29: helium dilution

C1 x V1 = C2 x (V1 + Vlung) | Vlung = V1 x (C1 / C2 - 1)

V1 is the initial spirometer volume; C1 and C2 are initial and final helium concentrations. The amount of helium stays constant.

GivenSubstitutionAnswer
V1 = 8 L; C1 = 5%; C2 = 4%8 x (0.05 / 0.04 - 1)2 L of lung gas at connection

This is FRC only if connection was at the end of a normal expiration. Then RV = FRC - ERV. A leak or trapped gas makes the simple dilution result unreliable.

Other calculations

QuantityFormulaExample
Respiratory ratef = 60 / cycle duration in seconds3-second cycle -> 20 breaths/min
Minute ventilationVE = VT x f0.4 L x 20/min = 8 L/min
Alveolar ventilationVA = (VT - VD) x f(0.5 - 0.15) L x 12/min = 4.2 L/min
Bohr equationVD / VT = (PACO2 - mixed expired PCO2) / PACO2(40 - 28) / 40 = 0.30; VD = 0.30 x VT
Tiffeneau indexFEV1 / VC x 100%2 L / 4 L x 100% = 50%: low
Arteriovenous oxygen differenceArterial O2 content - mixed venous O2 content200 - 152 = 48 mL O2/L blood

Graphs

30. Respiratory rate from a spirogram

PDF p. 13
  • Horizontal axis: time. Vertical axis: lung volume. One full rise-and-fall is one breath.
  • Respiratory rate = complete breaths / time in minutes. If time is in seconds, multiply by 60.
  • This particular drawing has no time scale, so a numerical breathing rate cannot be calculated.

31. FRC and VC from a spirogram

PDF p. 13
  • FRC: the volume at the end of a quiet expiration. On this graph it is about 3.2 L.
  • VC: maximal inspiration minus maximal expiration. Here: 6 - 2 = 4 L.
  • The figure supplies an absolute lung-volume scale. Ordinary spirometry alone cannot establish RV or FRC.

32a. Label the lung volumes

PDF p. 14
  • Small quiet breath: VT. Extra air above it: IRV. Extra air expired below it: ERV. Gas left after maximal expiration: RV.
  • VC = IRV + VT + ERV. IC = VT + IRV. FRC = ERV + RV. TLC = VC + RV.
LabelVolume or capacity
1VT: tidal volume
2IRV: inspiratory reserve volume
3ERV: expiratory reserve volume
4RV: residual volume
5VC: vital capacity
6IC: inspiratory capacity
7FRC: functional residual capacity
8TLC: total lung capacity

32b. Read the flow-volume loops

PDF p. 14
  • Vertical axis: airflow in L/s. Horizontal axis: volume in L. The top peak is PEF; the lower peak is inspiratory flow.
  • Left: the horizontal axis gives absolute lung volume. TLC = 6 L; RV = 2 L; FVC = 4 L; PEF is about 8 L/s.
  • Right: the axis gives expired volume, starting at zero. FVC is about 4.5 L; PEF is about 8 L/s. RV and TLC cannot be read from it.
  • Volume is measured in L; flow is measured in L/s. A zero on an expired-volume axis does not mean the lungs contain no gas.